Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
PLoS One ; 16(11): e0257549, 2021.
Article in English | MEDLINE | ID: covidwho-1793615

ABSTRACT

Particulate generation occurs during exercise-induced exhalation, and research on this topic is scarce. Moreover, infection-control measures are inadequately implemented to avoid particulate generation. A laminar airflow ventilation system (LFVS) was developed to remove respiratory droplets released during treadmill exercise. This study aimed to investigate the relationship between the number of aerosols during training on a treadmill and exercise intensity and to elucidate the effect of the LFVS on aerosol removal during anaerobic exercise. In this single-center observational study, the exercise tests were performed on a treadmill at Running Science Lab in Japan on 20 healthy subjects (age: 29±12 years, men: 80%). The subjects had a broad spectrum of aerobic capacities and fitness levels, including athletes, and had no comorbidities. All of them received no medication. The exercise intensity was increased by 1-km/h increments until the heart rate reached 85% of the expected maximum rate and then maintained for 10 min. The first 10 subjects were analyzed to examine whether exercise increased the concentration of airborne particulates in the exhaled air. For the remaining 10 subjects, the LFVS was activated during constant-load exercise to compare the number of respiratory droplets before and after LFVS use. During exercise, a steady amount of particulates before the lactate threshold (LT) was followed by a significant and gradual increase in respiratory droplets after the LT, particularly during anaerobic exercise. Furthermore, respiratory droplets ≥0.3 µm significantly decreased after using LFVS (2120800±759700 vs. 560 ± 170, p<0.001). The amount of respiratory droplets significantly increased after LT. The LFVS enabled a significant decrease in respiratory droplets during anaerobic exercise in healthy subjects. This study's findings will aid in exercising safely during this pandemic.


Subject(s)
Air Conditioning/methods , COVID-19/prevention & control , Exercise/physiology , Particulate Matter/chemistry , Adult , Aerosols/chemistry , Air Filters , Anaerobic Threshold/physiology , COVID-19/metabolism , Exercise Test/methods , Exhalation/physiology , Female , Heart Rate/physiology , Humans , Japan , Lactic Acid/metabolism , Male , Oxygen Consumption/physiology , Respiration , Respiratory System/physiopathology , Running/physiology , SARS-CoV-2/pathogenicity , Ventilation/methods
2.
Chest ; 160(4): 1388-1396, 2021 10.
Article in English | MEDLINE | ID: covidwho-1248851

ABSTRACT

BACKGROUND: The role of portable high-efficiency particulate air (HEPA) filters for supplemental aerosol mitigation during exercise testing is unknown and might be relevant during COVID-19 pandemic. RESEARCH QUESTION: What is the effect of portable HEPA filtering on aerosol concentration during exercise testing and its efficiency in reducing room clearance time in a clinical exercise testing laboratory? STUDY DESIGN AND METHODS: Subjects were six healthy volunteers aged 20 to 56 years. In the first experiment, exercise was performed in a small tent with controlled airflow with the use of a stationary cycle, portable HEPA filter with fume hood, and particle counter to document aerosol concentration. Subjects performed a four-stage maximal exercise test that lasted 12 min plus 5 min of pretest quiet breathing and 3 min of active recovery. First, they exercised without mitigation then with portable HEPA filter running. In a separate experiment, room aerosol clearance time was measured in a clinical exercise testing laboratory by filling it with artificially generated aerosols and measuring time to 99.9% aerosol clearance with heating, ventilation, and air conditioning (HVAC) only or HVAC plus portable HEPA filter running. RESULTS: In the exercise experiment, particle concentrations reached 1,722 ± 1,484/L vs 96 ± 124/L (P < .04) for all particles (>0.3 µm), 1,339 ± 1,281/L vs 76 ± 104/L (P < .05) for smaller particles (0.3 to 1.0 µm), and 333 ± 209/L vs 17 ± 19/L (P < .01) for larger particles (1.0 to 5.0 µm) at the end of the protocol in a comparison of mitigation vs portable HEPA filter. Use of a portable HEPA filter in a clinical exercise laboratory clearance experiment reduced aerosol clearance time 47% vs HVAC alone. INTERPRETATION: The portable HEPA filter reduced the concentration of aerosols generated during exercise testing by 96% ± 2% for all particle sizes and reduced aerosol room clearance time in clinical exercise testing laboratories. Portable HEPA filters therefore might be useful in clinical exercise testing laboratories to reduce the risk of COVID-19 transmission.


Subject(s)
Aerosols/analysis , Air Conditioning/methods , Air Filters , COVID-19/diagnosis , Pandemics , Adult , COVID-19/metabolism , Female , Healthy Volunteers , Humans , Male , Middle Aged , Particle Size , Young Adult
3.
Air Med J ; 40(1): 54-59, 2021.
Article in English | MEDLINE | ID: covidwho-1060089

ABSTRACT

OBJECTIVE: The aeromedical transport of coronavirus patients presents risks to clinicians and aircrew. Patient positioning and physical barriers may provide additional protection during flight. This paper describes airflow testing undertaken on fixed wing and rotary wing aeromedical aircraft. METHODS: Airflow testing was undertaken on a stationary Hawker Beechcraft B200C and Leonardo Augusta Westland 139. Airflow was simulated using a Trainer 101 (MSS Professional A/S, Odense Sø, Syddanmark, Denmark) Smoke machine. Different cabin configurations were used along with variations in heating, cooling, and ventilation systems. RESULTS: For the Hawker Beechcraft B200C, smoke generated within the forward section of the cabin was observed to fill the cabin to a fluid boundary located in-line with the forward edge of the cargo door. With the curtain closed, smoke was only observed to enter the cockpit in very small quantities. For the Leonardo AW139, smoke generated within the cabin was observed to expand to fill the cabin evenly before dissipating. With the curtain closed, smoke was observed to enter the cockpit only in small quantities CONCLUSION: The use of physical barriers in fixed wing and rotary wing aeromedical aircraft provides some protection to aircrew. Optimal positioning of the patient is on the aft stretcher on the Beechcraft B200C and on a laterally orientated stretcher on the AW139. The results provide a baseline for further investigation into methods to protect aircrew during the coronavirus pandemic.


Subject(s)
Air Ambulances , Air Conditioning/methods , Air Movements , COVID-19/prevention & control , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Ventilation/methods , Air Conditioning/instrumentation , COVID-19/transmission , Humans , Ventilation/instrumentation
4.
ACS Chem Neurosci ; 11(20): 3177-3179, 2020 10 21.
Article in English | MEDLINE | ID: covidwho-802916

ABSTRACT

Several lines of evidence suggest the role of air-conditioning systems in the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Furthermore, the likelihood of novel coronavirus to take refuge inside a microbial Trojan horse, that is, Acanthamoeba, can further enhance possibility of SARS-CoV-2 transmission in the environment. Here we propose the use of various disinfection strategies that can be employed using filters with antimicrobial fabricated surfaces or using UV irradiation to achieve germicidal properties for removal of pathogenic microbes such as SARS-CoV-2 and amoebae in the ventilation systems.


Subject(s)
Air Conditioning/methods , Air Filters/virology , Air Pollution, Indoor/prevention & control , Coronavirus Infections/prevention & control , Coronavirus Infections/transmission , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Pneumonia, Viral/transmission , Betacoronavirus/pathogenicity , COVID-19 , Disinfection/methods , Humans , SARS-CoV-2
5.
Crit Care ; 24(1): 194, 2020 05 06.
Article in English | MEDLINE | ID: covidwho-186516

ABSTRACT

The aim of this review is to describe variation in standards and guidelines on 'heating, ventilation and air-conditioning (HVAC)' system maintenance in the intensive care units, across the world, which is required to maintain good 'indoor air quality' as an important non-pharmacological strategy in preventing hospital-acquired infections. An online search and review of standards and guidelines published by various societies including American Institute of Architects (AIA), American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), Centers for Disease Control and Prevention (CDC), Department of Health Estates and Facilities Division, Health Technical Memorandum 2025 (HTM) and Healthcare Infection Control Practices Advisory Committee (HICPAC) along with various national expert committee consensus statements, regional and hospital-based protocols available in a public domain were retrieved. Selected publications and textbooks describing HVAC structural aspects were also reviewed, and we described the basic structural details of HVAC system as well as variations in the practised standards of HVAC system in the ICU, worldwide. In summary, there is a need of universal standards for HVAC system with a specific mention on the type of ICU, which should be incorporated into existing infection control practice guidelines.


Subject(s)
Air Conditioning/methods , Heating/methods , Ventilation/methods , Air Conditioning/trends , Air Pollution, Indoor/analysis , Heating/trends , Humans , Infection Control/instrumentation , Infection Control/methods , Infection Control/trends , Intensive Care Units/organization & administration , Particulate Matter/adverse effects
6.
Med Hypotheses ; 141: 109781, 2020 Aug.
Article in English | MEDLINE | ID: covidwho-116780

ABSTRACT

The world is facing a pandemic of unseen proportions caused by a corona virus named SARS-CoV-2 with unprecedent worldwide measures being taken to tackle its contagion. Person-to-person transmission is accepted but WHO only considers aerosol transmission when procedures or support treatments that produce aerosol are performed. Transmission mechanisms are not fully understood and there is evidence for an airborne route to be considered, as the virus remains viable in aerosols for at least 3 h and that mask usage was the best intervention to prevent infection. Heating, Ventilation and Air Conditioning Systems (HVAC) are used as a primary infection disease control measure. However, if not correctly used, they may contribute to the transmission/spreading of airborne diseases as proposed in the past for SARS. The authors believe that airborne transmission is possible and that HVAC systems when not adequately used may contribute to the transmission of the virus, as suggested by descriptions from Japan, Germany, and the Diamond Princess Cruise Ship. Previous SARS outbreaks reported at Amoy Gardens, Emergency Rooms and Hotels, also suggested an airborne transmission. Further studies are warranted to confirm our hypotheses but the assumption of such way of transmission would cause a major shift in measures recommended to prevent infection such as the disseminated use of masks and structural changes to hospital and other facilities with HVAC systems.


Subject(s)
Air Microbiology , Betacoronavirus/isolation & purification , Coronavirus Infections/transmission , Environment, Controlled , Pandemics , Pneumonia, Viral/transmission , Ventilation , Aerosols , Air Conditioning/adverse effects , Air Conditioning/instrumentation , Air Conditioning/methods , Air Pollution, Indoor , COVID-19 , Coronavirus Infections/prevention & control , Cross Infection/transmission , Equipment Contamination , Equipment Design , Equipment Failure , Fomites/virology , Heating/adverse effects , Heating/instrumentation , Heating/methods , Humans , Legionnaires' Disease/epidemiology , Legionnaires' Disease/transmission , Models, Biological , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , SARS-CoV-2 , Sanitary Engineering/instrumentation , Severe Acute Respiratory Syndrome/epidemiology , Severe Acute Respiratory Syndrome/transmission , Sewage/virology , Ventilation/instrumentation , Ventilation/methods
SELECTION OF CITATIONS
SEARCH DETAIL